Home › Articles › Volume 9, Issue 1 › To Compare the Diagnostic Sensitivity of ZN (Ziehl-N...
Moradabad, India
Original Article
Pulmonary Medicine

To Compare the Diagnostic Sensitivity of ZN (Ziehl-Neelsen) Staining, CBNAAT (Cartridge Based Nucleic Acid Amplification Test) and Mycobacterium Culture of BAL (Bronchoalveolar Lavage) Fluid among Sputum Smear Negative or Non- Sputum Producing Patients with Suspected Pulmonary Tuberculosis


Volume 9, Issue 1, Pages 14-19

Authors

Vipin Deo Tiwari1, Mazher Maqusood2, G. Ramakrishna3, Rajul Rastogi4
Affiliation:
1Junior Resident, Department of Pulmonary Medicine, Teerthanker Mahaveer Medical College & Research Centre, Moradabad (UP),
2Professor, Department of Pulmonary Medicine, Teerthanker Mahaveer Medical College & Research Centre, Moradabad (UP),
3HOD & Professor, Department of Pulmonary Medicine, Teerthanker Mahaveer Medical College & Research Centre, Moradabad (UP),
4Associate Professor, Department of Radiology, Teerthanker Mahaveer Medical College & Research Centre, Moradabad (UP).

Corresponding Author

Mazher Maqusood

Abstract

Background: Compare the diagnostic sensitivity of ZN staining and CBNAAT using Mycobacterium Culture as a gold standard in BAL fluid among sputum smear negative or non- sputum producing patients with suspected pulmonary tuberculosis. Subjects and Methods: Our prospective observational study was conducted on 76 patients either attending Outpatient Department or being admitted in the department of Pulmonary Medicine, Teerthanker Mahaveer Medical College & Research Centre, Moradabad (UP). BAL sample obtained using a flexible fibre-optic bronchoscope from sputum smear negative or non- sputum producing patients with suspected pulmonary tuberculosis. Sample was divided into three parts and send the BAL fluid for CBNAAT, ZN staining, and Mycobacterium liquid culture and compare the diagnostic sensitivity of ZN staining and CBNAAT using Mycobacterium Culture as a gold standard in BAL fluid. Results: Our study was carried out on 76 patients, ZN staining detected positive and negative in BAL samples among 17.1% and 82.9% respectively. CBNAAT detected positive and negative in BAL samples among 68.72% and 31.6% respectively. Among the positive detected specimens, rifampicin resistance and sensitive were found among 4 (5.56%) and 48 (63.16%) specimens respectively.MTB detected positive and negative in BAL samples among 51.3% and 48.7% of the subjects respectively. The gold standard BAL-MTB liquid culture was used to test the efficacy of ZN staining to detect the BAL specimen. Sensitivity, specificity, PPV, NPV, and Accuracy of ZN in the detection of BAL specimen were 23.08%, 89.19%, 69.23%, 52.38%, and 55.26% respectively. Sensitivity, specificity, PPV, NPV and Accuracy of CBNAAT in detection of BAL specimen were 92.31%, 66.76%, 79.23%, 87.50% and 75% respectively. Conclusion: Gene Xpert MTB/RIF assay is efficient and reliable technique for the smear negative cases. Its simplicity, sensitivity, speed and automation, make this technique a very attractive tool for diagnosis of pulmonary tuberculosis in smear negative cases of TB suspects. Meanwhile it has an added advantage of detection of multi-drug resistant cases.

Keywords

BAL- Bronchoalveolar lavage, CBNAAT- Cartridge based nucleic acid amplification test, PTB- Pulmonary tuberculosis, ZN- Ziehl-neelsen.

History

Received 01 March 2020

Accepted 01 March 2020

DOI

10.47009/ajmr.2020.9.1.PM4

Author Notes

Corresponding Author: Dr. Mazher Maqusood, Professor, Department of Pulmonary Medicine, Teerthanker Mahaveer Medical College & Research Centre, Moradabad (UP). Email:

Open Access

It is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits authors to retain ownership of the copyright for their content, and allow anyone to download, reuse, reprint, modify, distribute and/or copy the content as long as the original authors and source are cited. https://creativecommons.org/licenses/by/4.0/

Copyright

Copyright (c) 2020 Asian Journal of Medical Research

Cite this Article

Formats

                                                
Actions
Download PDF
Metrics
7
Downloads
7
Views
Journal
Journal Asian Journal of Medical Research
Volume Volume 9
Issue Issue 1
Year 2020

Purchase access plans

Select the plan that best fits your need

Loading plans...

Statistics:

Views: 0
Downloads: 0

Asian Journal of Medical Research (AJMR) is an international, peer-reviewed, quarterly open-access journal publishing advanced research across medical specialties.

Quick Links

For Authors

© 2026 Asian Journal of Medical Research. All Rights Reserved.Designed and Developed By Kryoni