Home › Articles › Volume 8, Issue 3 › Comparative Evaluation of I Gel and Cuffed ET Tube f...
Moradabad, India
Original Article
Anaesthesia

Comparative Evaluation of I Gel and Cuffed ET Tube for Anesthesia in Abdominal Surgery


Volume 8, Issue 3, Pages 8-10

Authors

Anirudh Prasad Mandal1, Narendra Kumar2, Rakesh Kumar1
Affiliation:
1Senior Resident, Department of Anesthesia, GMC Bettiah,
2Associate Professor & HOD, Department of Anesthesia, GMC Bettiah.

Corresponding Author

Anirudh Prasad Mandal

Abstract

Background: This study aims to test and compare Endo tracheal tube and i-gel in terms of their: Efficacy: Difference in the leak fraction between two airway devices before and after pneumoperitoneum with different tidal volumes andcomparison of oropharyngeal leak pressure. Ease of insertion: Number of attempts required for optimal positioning. Subjects and Methods: Sixty patients, ASA I–II, were randomly selected to the study. Standard anaesthetic technique was used for all patients. The i-gel was then inserted. The lungs were ventilated at three different tidal volumes (6, 8 and 10 ml kg l) using volume controlled ventilation (VCV). The leak volume was calculated as the difference between the inspired and expired tidal volumes. The leak fraction was also calculated as the leak volume divided by the inspired tidal volume. These observations were recorded with every tidal volume before and after pneumoperitoneum with the i-gel and the conventional tracheal tube. Results: We found oropharyngeal leak pressure for i gel as 26cm of H2O and there was no leak in endotracheal tube group even at 40 cm of H2O peak air way pressure. Before and after pneumoperitoneum there was no statistically significant difference in leak fraction or leak volume between i-gel and tracheal tube at tidal volume 6ml kg−1. At 8 and 10 ml kg−1 there was statistically significant difference between i-gel and tracheal tube both before and after pneumoperitoneum. Conclusion: In our study we found that i-gel airway can be used safely and effectively during volume controlled ventilation with low and moderate tidal volumes.

Keywords

I-gel, Leak fraction, Pneumoperitoneum, Cholecystectomy.

History

Received 01 September 2019

Accepted 01 September 2019

DOI

10.21276/ajmr.2019.8.3.AN3

Author Notes

Corresponding Author: Dr. Anirudh Prasad Mandal, Senior Resident, Department of Anesthesia, GMC Bettiah.

Open Access

It is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits authors to retain ownership of the copyright for their content, and allow anyone to download, reuse, reprint, modify, distribute and/or copy the content as long as the original authors and source are cited. https://creativecommons.org/licenses/by/4.0/

Copyright

Copyright: © the author(s), 2019.

Cite this Article

Formats

                                                
Actions
Download PDF
Metrics
11
Downloads
12
Views
Journal
Journal Asian Journal of Medical Research
Volume Volume 8
Issue Issue 3
Year 2019

Purchase access plans

Select the plan that best fits your need

Loading plans...

Statistics:

Views: 0
Downloads: 0

Asian Journal of Medical Research (AJMR) is an international, peer-reviewed, quarterly open-access journal publishing advanced research across medical specialties.

Quick Links

For Authors

© 2026 Asian Journal of Medical Research. All Rights Reserved.Designed and Developed By Kryoni