Comparison The Property Of Tungsten And Lead For Protection Against Radiotherapy In Different Thickness And Position As Shielding Materials’


Volume 6, Issue 4, Pages 8-10

Authors

Kuson Tuntiwong1, Siripatra Patchanee1, Suthamat Wattanachaiyasit1, Urairat Kaewbunperm1
Affiliation:
1Faculty of dentistry, Thammasat university-Rangsit campus, Pathumthani, Thailand.

Corresponding Author

Kuson Tuntiwong

Abstract

Background: Osteoradionecrosis (ORN) is a late complication of irradiation that does not resolve spontaneous. The aim of this study was to evaluate the effectiveness of holding tungsten and lead position to decrease radiation dose. Methods: The research was performed by using dried skull model covered with paraffin wax representing tissue. The protective devices had 2 models; the first model attached with tungsten or lead sheets (size 2.5x3.5 cm2 12 mm. in thickness), were constructed and placed in the both sides of mandible buccally. The others was similar to the first model, but the difference of it was constructed and placed in the mandible linguo- buccally. The 6 MV (2Gy) of photon was radiated, and then the percentages of remained relative doses in the mandible at different areas were measured. Results: The unshielded dried skull phantom radiation dose average ranged from 2.029 to 3.620 nCb. The first models, the percentage mean of remained relative dose were 67.335% and 46.878% in tungsten and lead respectively. The others were 57.494% and 40.677% in tungsten and lead respectively. The tungsten protective device significantly decreased the percentage mean of transmission dose more than the lead shield (p = 0.05), the percentage mean of transmission dose of both shields was difference significantly in each location (p = 0.05) and the first model shield had significantly difference in compare with the others (p = 0.05), exception in the model 2 was 12 mm. tungsten when right radiation beam entried. Conclusion:The tungsten protective device can decrease the remained doses more than the lead device.The position holding the metals should be the buccally.

Key Words

Osteoradionecrosis, Radiation, Lead, Tungsten, Intraoral shield, Head and neck cancer.

History

Received 20 May 2017

Accepted 16 June 2017

Author Notes

Address for correspondence* Dr. Kuson Tuntiwong Faculty of dentistry, Thammasat university-Rangsit campus Pathumthani, Thailand.

Open Access

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License . https://creativecommons.org/licenses/by-nc/4.0/

Copyright

Copyright (c) 2017 Asian Journal of Medical Research

Cite this Article

Formats

                                                
Actions
Download PDF
Metrics
10
Downloads
11
Views
Journal
Journal Asian Journal of Medical Research
Volume Volume 6
Issue Issue 4
Year 2017

Purchase access plans

Select the plan that best fits your need

Loading plans...

Statistics:

Views: 0
Downloads: 0

Asian Journal of Medical Research (AJMR) is an international, peer-reviewed, quarterly open-access journal publishing advanced research across medical specialties.

Quick Links

For Authors

© 2026 Asian Journal of Medical Research. All Rights Reserved.Designed and Developed By Kryoni